Controller products with Modbus capability are used where a Delta I/O controller already exists, and there is a need to add Modbus devices as part of the same mechanical. ![]() ZHT4400 supports modbus RTU, a question-and-answer communication method, which is simple, versatile and easy to use. Gateway products, pre-loaded with Modbus, provide a gateway to BACnet for multiple Modbus devices communicating on the same Modbus network (5, 15, or 30 Modbus slave devices). It can be widely used in pump control, access control monitoring, lighting control, such as valve monitor application scenario.ĭual watchdogs, stable operation without downtime for 24 hoursĬommunication baud rate: 1200 2400 4800 9600 14400 19200 38400 43000 57600 76800 115200 128000 230400 256000 460800 921600 (can be modified by software, default 115200)Ĭommunication protocol: Support Modbus RTU protocolĠ1-30 device addresses can be set, and 1-30 address codes can be set with the 5-digit address dial switch KUNBUS-IC modules are certified 100 % and have also proven themselves in the safety sector.ZHT4400 is a serial port control module that provides 4 DI, 4 DO and a RS485 interface, support the standard Modbus RTU protocol, support dry wet node detection, support relay delay shut down after opening, we provide comprehensive technical supports. Because of the control-independent operation of the KUNBUS-IC Modes module, the load of the processor of the control is reduced completely. Contact a supplier or the parent company directly to get a quote or to find out a price or your closest point of sale. IO Studio is its PC software for setting communication. Find out all of the information about the Beijing Tengcon Technology Co.,Ltd. The bus is galvanically separated up to 1.5 kV from the application. IO-16DI - 16 digital inputs These modules are used with HMI, PLC or SCADA via Modbus RTU protocol. A second serial interface enables use as a debugging and configuration interface (CDI) for connection of a terminal. These can be configured freely as IN or OUT (for example 27 x output and 5 x input). ![]() 32 x 8 bytes can be used for the input and output signals. ![]() The first method is via a second Modbus RTU serial UART interface, and the second is via an SSC shift register interface (for devices without a processor). Your application can be connected via two different interfaces. In addition to the time and cost savings with your product introduction, you benefit also through lower development expenses with the integration of Modbus RTU. Your control or application becomes Modbus-enabled in the shortest time by use of our KUNBUS-IC Modbus RTU piggyback card.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |